{"id":1009619,"date":"2021-01-25T15:19:11","date_gmt":"2021-01-25T12:19:11","guid":{"rendered":"https:\/\/uabio.org\/?p=9619"},"modified":"2021-02-05T01:19:23","modified_gmt":"2021-02-04T22:19:23","slug":"perehid-na-vde-do-2050-roku-deshevshyj-za-pidtrymku-nayavnogo-stanu-energosystemy","status":"publish","type":"uabio_document","link":"https:\/\/uabio.org\/en\/materials\/9619\/","title":{"rendered":"The transition to RES by 2050 is cheaper than maintaining the current state of the power system"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">The Finnish company W\u00e4rtsil\u00e4 Corporation has modeled two scenarios for the optimal development of Ukraine&#8217;s energy system with the lowest cost until 2050.&nbsp;The study used a proven energy simulation software <a rel=\"noreferrer noopener\" href=\"https:\/\/energyexemplar.com\/plexos-world\/\" target=\"_blank\">PLEXOS<\/a>, designed to find the cost-optimal solution for each scenario based on the applied constraints.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">The first scenario \u2013 a cost-optimised power system with the lowest total system cost and no RES targets<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">In both scenarios, PLEXOS built an optimal power generation mix each year and optimized dispatch every two hours during the 30-year planning horizon. <\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/uabio.org\/wp-content\/uploads\/2021\/01\/Znimok-ekrana-2021-02-04-o-16.59.07-e1612476777926.png\" alt=\"\" class=\"wp-image-1009673\" width=\"980\" height=\"462\" srcset=\"https:\/\/uabio.org\/wp-content\/uploads\/2021\/01\/Znimok-ekrana-2021-02-04-o-16.59.07-e1612476777926.png 2308w, https:\/\/uabio.org\/wp-content\/uploads\/2021\/01\/Znimok-ekrana-2021-02-04-o-16.59.07-e1612476777926-768x363.png 768w, https:\/\/uabio.org\/wp-content\/uploads\/2021\/01\/Znimok-ekrana-2021-02-04-o-16.59.07-e1612476777926-1536x725.png 1536w, https:\/\/uabio.org\/wp-content\/uploads\/2021\/01\/Znimok-ekrana-2021-02-04-o-16.59.07-e1612476777926-2048x967.png 2048w\" sizes=\"auto, (max-width: 980px) 100vw, 980px\" \/><\/figure><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">The modelled power system provides the lowest cost of all potential options over the time period until 2050. The PLEXOS optimiser built up an increasing amount of wind and solar capacity as time progressed. Major solar buildout starts after 2025 due to the expected falling solar and storage prices. A strong overbuild of renewables and flexible gas starts around 2030. The total system size will reach 126 GW in 2050.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">The second scenario \u2013 a 100% decarbonized system where system-level CO2 emissions fall to zero by 2050<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">In the 100% renewable energy scenario, PLEXOS had an additional target to achieve a fully decarbonised system by 2050. <\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/uabio.org\/wp-content\/uploads\/2021\/01\/Znimok-ekrana-2021-02-04-o-16.59.28.png\" alt=\"\" class=\"wp-image-1009672\" width=\"980\" height=\"505\" srcset=\"https:\/\/uabio.org\/wp-content\/uploads\/2021\/01\/Znimok-ekrana-2021-02-04-o-16.59.28.png 2308w, https:\/\/uabio.org\/wp-content\/uploads\/2021\/01\/Znimok-ekrana-2021-02-04-o-16.59.28-768x397.png 768w, https:\/\/uabio.org\/wp-content\/uploads\/2021\/01\/Znimok-ekrana-2021-02-04-o-16.59.28-1536x793.png 1536w, https:\/\/uabio.org\/wp-content\/uploads\/2021\/01\/Znimok-ekrana-2021-02-04-o-16.59.28-2048x1058.png 2048w\" sizes=\"auto, (max-width: 980px) 100vw, 980px\" \/><\/figure><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">To reach a fully decarbonised power system compared to the cost-optimised scenario, 26 GW more wind and solar power is needed and Power-to-Gas (P2G) conversion is also necessary.<br><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The P2G process means that excess wind and solar electricity can be used to produce renewable synthetic gas through hydrogen electrolysis and methane synthesis. The gas is then liquefied and stored, and later regasified for use in flexible thermal power plants.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/uabio.org\/wp-content\/uploads\/2021\/01\/Znimok-ekrana-2021-02-04-o-17.06.13.png\" alt=\"\" class=\"wp-image-1009674\" width=\"980\" height=\"328\"\/><\/figure><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">By the way, this is not the first study of this type.\u00a0For example, in 2016, Finnish experts from <a rel=\"noreferrer noopener\" href=\"https:\/\/www.lut.fi\/web\/en\" target=\"_blank\">Lappeenranta-Lahti University of Technology (LUT)<\/a> presented a scenario of the power system transition to 100% RES by 2050 with similar results \u2013 lower final cost of electricity, the need to install additional balancing capacity, shunting generation and usage of Power technology\u00a0-To-Gas.\u00a0Details of the project <a rel=\"noreferrer noopener\" href=\"http:\/\/www.neocarbonenergy.fi\/wp-content\/uploads\/2016\/02\/3_Child.pdf\" data-type=\"URL\" data-id=\"http:\/\/www.neocarbonenergy.fi\/wp-content\/uploads\/2016\/02\/3_Child.pdf\" target=\"_blank\">by the link<\/a>.<\/p>\n\n\n\n<hr class=\"wp-block-separator is-style-wide\"\/>\n\n\n\n<p class=\"wp-block-paragraph\"><em>More information in the W\u00e4rtsil\u00e4<\/em> report<em>: in <a rel=\"noreferrer noopener\" href=\"https:\/\/drive.google.com\/file\/d\/1zS3HdRk3bTlEoShXOf0XMCjFL0kpww2a\/view\" data-type=\"URL\" data-id=\"https:\/\/drive.google.com\/file\/d\/1zS3HdRk3bTlEoShXOf0XMCjFL0kpww2a\/view\" target=\"_blank\">Ukrainian<\/a> and in <a rel=\"noreferrer noopener\" href=\"https:\/\/drive.google.com\/file\/d\/1NbE8aP9q7B8e7UM9b6CS6og1yz3KFVBC\/view\" data-type=\"URL\" data-id=\"https:\/\/drive.google.com\/file\/d\/1NbE8aP9q7B8e7UM9b6CS6og1yz3KFVBC\/view\" target=\"_blank\">English<\/a>.<\/em><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The Finnish company W\u00e4rtsil\u00e4 Corporation has modeled two scenarios for the optimal development of Ukraine&#8217;s energy system with the lowest cost until 2050.&nbsp;The study used a proven energy simulation software PLEXOS, designed to find the cost-optimal solution for each scenario based on the applied constraints. The first scenario \u2013 a cost-optimised power system with the [&hellip;]<\/p>\n","protected":false},"featured_media":1009620,"template":"","categories":[1000018,1000007],"uabio_document_type":[1001006],"class_list":["post-1009619","uabio_document","type-uabio_document","status-publish","has-post-thumbnail","hentry","category-analytics","category-materials","uabio_document_type-analytics"],"_links":{"self":[{"href":"https:\/\/uabio.org\/en\/wp-json\/wp\/v2\/uabio_document\/1009619","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/uabio.org\/en\/wp-json\/wp\/v2\/uabio_document"}],"about":[{"href":"https:\/\/uabio.org\/en\/wp-json\/wp\/v2\/types\/uabio_document"}],"version-history":[{"count":0,"href":"https:\/\/uabio.org\/en\/wp-json\/wp\/v2\/uabio_document\/1009619\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/uabio.org\/en\/wp-json\/wp\/v2\/media\/1009620"}],"wp:attachment":[{"href":"https:\/\/uabio.org\/en\/wp-json\/wp\/v2\/media?parent=1009619"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/uabio.org\/en\/wp-json\/wp\/v2\/categories?post=1009619"},{"taxonomy":"uabio_document_type","embeddable":true,"href":"https:\/\/uabio.org\/en\/wp-json\/wp\/v2\/uabio_document_type?post=1009619"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}